The active ventilation
and internal temperature
control system.

Is supplied in the base set with cabinets:

SYSRACKS SRF 
SYSRACKS PR

  • Shipping within 48 h.
  • Return purchased items and get all your money back.
  • Accepting orders 24/7
  • Order overs 999usd this product and earn 100 special loyalty points!
  • Bonus Gift on order overs 999usd

- Easy access, easy setup and adjustment;
- A stable operation of the active equipment by creating a comfortable temperature range;
- Saving resource active ventilation devices;
- Energy savings;
- Removal of the constant noise problems when working fan modules (important when installing the cabinet in public areas) ...

Parameters

  • power input: 110B/220B;
  • power consumption: <3 Вт;
  • fan and Light output:110B/220B-5;
  • range:19,9-99,9C;
  • two independent channel control,
    two temperature sensors NTC10K.

Settings

The control unit has three types of modes:

  • normal mode;
  • adjustment settings and
  • reset to factory defaults.

While pressing and hold the SET button, it switches to adjustment mode. Hold down the SET button more than 3 seconds, reset to factory default settings. A single press button SET in regulatory regimes or initialization switches to the operating mode. Use the UP- button and DOWN- button to modify the selected parameter.

Code
Function
Content Control
Range
Factory
settings
Note
F1 A channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F2 A channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting range of operation. Use the up and down button peak value. Short press SET to set the default settings
F3 B channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F4 B channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting temperature. Use the up and down having set the temperature value. Short press SET to set the default settings
F5 Temperature correction -10+10 0,0 The calibration function (correction) of reading between the actual temperature and the determined unit
F6 Start-up delay 0-5 2,0 Press and hold the SET button to select the setting delay. Use the up and down to set the desired value. Short press SET to set the default settings.
E1 A channel error A channel self-testing error
E2 B channel error B channel self-testing error

  • Cut the power cable in half;
  • Strip the blue and brown wires on both male and female ends;
  • Use diagram to plug the Power Supply (male end),
    Cooling panel (female end) and thermosensors to the Air Control System device;
  • Place the Air Control System device into the top panel and plug in;
  • Set the temperature regime.