What Is A 19-Inch Rack? photo
Floor Standing Server Racks
  • SRF800 Floor-Standing Server Cabinets
  • SRF900G Light-Grey Floor-Standing Server Cabinets
  • SRF1000 Floor-Standing Server Cabinets
What Is A 19-Inch Rack? photo
Wall-Mounted Server Rack Cabinets
  • SRW450 Wall-mounted Server Cabinets
  • SRW600 Wall-mounted Server Cabinets
  • SRW600G Light-Grey Wall-mounted Server Cabinets
What Is A 19-Inch Rack? photo
Home Server Rack Cabinets
  • Small Server Racks
  • SYSRACKS WS
What Is A 19-Inch Rack? photo
Portable Server Rack Cabinets
  • SRW 900 Portable Server Cabinets
  • PR Portable Server Cabinets
What Is A 19-Inch Rack? photo
Soundproof Server Rack Cabinets
What Is A 19-Inch Rack? photo
Open Frame Server Racks
  • 4 Post Server Racks
  • 2 Post Server Racks
What Is A 19-Inch Rack? photo
Server Rack Accessories
  • Furniture Leveling Adjustable Feet
  • Server Rack Cooling Systems
  • Server Rack Shelves
  • Server Rack Power Supplies
What Is A 19-Inch Rack? photo
Server Rack Cable Management
  • Server Racks Cabling
  • Server Rack Patch Panels
Login
Forgot your password?
eye

Don't have an account? Join

You have an account? Login

eye

By joining, you agree to the Terms and Privacy Policy.

Recover password

Don't have an account? Join

Added to cart
✕
Checkout
Contact Us
  • Home
  • Blog
  • What Is A 19-Inch Rack?

What Is A 19-Inch Rack?

What is a 19in server cabinet

It’s no secret that every modern enterprise cannot function without computers and servers for Internet access, storage, and processing of information and datum. Companies use a lot of network devices, which must be placed somewhere and provide certain conditions for its operation. For the optimal performance of electronic equipment, it is necessary to accommodate hardware somewhere. Due to its ergonomic and technical features, the regarded type of server closet has been recognized as the best solution for closed server premises.

What is 19″?

19″ is the distance between the pairs of guides (mounting rails or extruders) to which the active and passive hardware is attached. The standard was introduced by EIA, the organization that is responsible for the objective collection of energy data, analysis, and economic predictions in the energy industry. According to the requirements set by the organization, the distance between the holes of the two fasteners should be 465 mm.

Benefits of 19-inch Cabinets for Housing Server Equipment

1. Accommodate a lot of apparatus in a relatively small area due to vertical mounting inside the server furniture. For example, a standard 19″ 42u 600x600mm wiring closet occupies only 0.36 m², and more than 30 standard 1U devices can be installed in this small area.

2. Sufficiently high reliability and durability. Some models can withstand loads of up to 800 kg. For example, TWT cabinets of the business series allow mounting and securely fixing devices that have a standard 19″ mount.

3. Simplify the process of installing computing devices. One person can cope with the task in a matter of minutes, and, if necessary, disassemble the equipment. Besides, no special tools are required.

4. Make it possible to both limit and delimit access to certain equipment and systems, due to being equipped with doors with latches.

5. Allow protecting the stored devices from moisture and electromagnetic radiation, as well as from dust, dirt, and other debris. Protection against electromagnetic radiation is ensured by the installation of a metal door and a protective earthing device. 6. Excellent designs and ergonomics. There are floor-standing, wall-mounted, portable models that can be installed even on office premises if required.

19U Cabinet Dimensions

When designing and choosing 19-inch cabinets, it is important to consider 19U rack dimensions: height, width, and depth.

A 19-inch rack width can vary from 600mm to 800mm. The wider the cabinet is, the more space between the side wall and the rail is left. The free space between the rail and the cabinet wall can be used for laying and mounting cables. The wider the cabinet is, the wider the vertical cable managers can be mounted on the side and the better the patch cords will be organized. Vertical cable managers are applied to route and organize patch and equipment cords.

The term “unit” is used to define the height of cabinets and the hardware mounted in them. One unit is equal to 4.445 cm or 1.75 inches. If the cabinet is 42u, this means that the enclosure can house a maximum of 42 1U pieces of equipment or 21 2u hardware items.

Another important parameter used to indicate overall dimensions is the depth of the cabinet. A 19-inch rack depth is indicated in millimeters and varies from 450 to 1200 mm.

Tips for Selecting the Most Suitable Model

1. It will be very problematic to mount and maintain equipment that is installed at a height of more than 2 meters, and the height of ceilings in server rooms does not always allow the installation of cabinets over 42u. Thus, make sure that the location is favorable for the chosen cabinet model.

2. When designing a data center, it is important to take into account the possibility of additional installation of active equipment in the future. The problem is related to airflow circulation. In a functioning data center, it will be quite difficult to upgrade server cabinets and racks due to problems arising from changes in hot and cold aisles and the possible violation of the thermal regime of the air conditioning system.

3. Another reason for space limitation is that before buying server furniture with standard 19 rack dimensions, you should foresee future system enlarging. It is recommended to leave at least 20%, or even preferably 30%, of free space for mounting additional equipment in the future. After all, it is impossible to foresee what will be required at the facility within 5-10 years.

Nowadays, any business requires a server room. However, the process of its organization is a complicated one and should be entrusted to experienced system administrators and engineers who are well-versed in the issue. When addressing skilled staff, they will help you design the best layout depending on your needs so that avoid hardware failure.

To share
Comment
Previous newsNext news

The Latest Posts

Server Rack Energy Consumption

Server Rack Energy Consumption

Network hardware requires constant feeding to ensure smooth operation. When perf...

Read more
Data Center Industry Overview

Data Center Industry Overview

Living in a digital era is connected to the regular use of network technologies ...

Read more
What Is Static and Dynamic Rack Load Capacity?

What Is Static and Dynamic Rack Load Capacity?

Data center furniture is produced to house IT equipment and accompanying accesso...

Read more
View all
What Is A 19-Inch Rack? photo
+1 (718) 616-9963
sales@sysracks.com

366 McArthur,
Montréal, QC H4T 1X8, Canada



616 Midland Ave,
Staten Island, NY 10306, USA



1500 Overland Ct,
West Sacramento, CA 95691-3490 US



Mon-Fri: 10am — 5pm

  • About Us
  • Blog
  • FAQ
    • Contact Us
    • Shipping Options
    • Returns and Exchanges
    • Warranty
      • Terms and Conditions

      Be the first to know about new product announcements, news, events, and more

      this is pypal
      What Is A 19-Inch Rack? photo
      What Is A 19-Inch Rack? photo
      What Is A 19-Inch Rack? photo

      2023 Sysracks.com. All Rights Reserved.

      Select your currency
      USD United States (US) dollar
      CAD Canadian dollar