
Server Rack Energy Consumption
Network hardware requires constant feeding to ensure smooth operation. When perf...
Read moreBonding (or grounding) is a system of protective measures, which is implemented to prevent electric shocks when touching metal parts of energy-powered equipment. The whole structure consists of a metal circuit, a ground bus, and a ground wire. Network hardware is connected to PDUs and constantly powered to perform smoothly. Thus, server cabinets require obligatory grounding to protect the maintenance staff.
Bonding is used worldwide, in all spheres since it is the best way to secure humans’ lives from sudden death. Grounding is found not only in industrial facilities but also in domestic households. Washing machines, bath tubes, and refrigerators are grounded in living apartments.
The main purpose of grounding data racks is to secure people from the harmful influence of electric circuits and prevent health problems and death in the case of serious damage to telecommunication systems.
Bonding is a reliable way to guarantee the protection of employees when maintaining telecommunication systems and server rooms.
The TIA and ANSI, international institutions for standardization and certification, standardize the requirements for manufacturers to produce physical machines in accordance with the set rules. The ANSI/TIA-942 standard is aimed at regulating the maintenance of network systems and data centers.
In order to pass certification, a data center should comply with this standard. It provides certificates on 4 rating levels. According to data rack grounding standards, Level 1 is characterized by minimal protection against emergencies and does not even require bonding. On the contrary, Level 4 sets the highest requirements since this standard is issued to healthcare institutions, financial organizations, and other major facilities. In this case, independent powering systems and distribution lines are built to guarantee a fault-tolerant infrastructure.
Setting data cabinet earthing requirements allows manufacturers to produce components that comply with international specifications and can be used worldwide. For manufacturers, it means a presence on the world market and the distribution of products in different markets.
Data centers consume 30 times more power than any office. Thus, it is important to guarantee the highest level of safety conditions. So, the installation of a grounded rack will be a good solution in any case. Here are some useful tips to keep in mind during the process:
The implementation of these tricks will help set up a reliable and 100% secure system that will protect workers and equipment, prolonging the lifetime of your network system and ensuring its smooth functioning.
Note that server racks and cabinets distributed by Sysrack are already grounded. Thus, it means that buyers won’t have to spend time and effort on proper bonding. Buying an earth-bonding data cabinet is an easy way to get a high-quality secure furniture piece and enjoy its security and performance. However, what is more, the lives of your employees are not at risk.
Regardless of what type of facility you have (be it an office, a commercial building, an industrial plant, or whatever), all components (both machinery and furniture) need protection. No one and nothing can guarantee 100% security without arranging a bonding system. Grounding is widely used in both domestic and industrial spheres. Yet, in system administration, it is highly required since IT equipment is vulnerable to changes, which can cause datum loss and provide a harmful effect not only on physical devices but also on human health and life.
Network hardware requires constant feeding to ensure smooth operation. When perf...
Read moreLiving in a digital era is connected to the regular use of network technologies ...
Read moreData center furniture is produced to house IT equipment and accompanying accesso...
Read more