6U (24"x24"x14") Wall Mount 19" Enclosure WR 6606.710

140.56 USD

Availability: Out of stock

Weight: 47.8 Lb.

Volume: 4272 in3.

Quantity of all packages: 1 pcs.

Size of package: 26X8X29 inch.


SYSMATRIX WR 6606.710

19 " Multi-function Wall Mount Enclosure

6U  24"x24"x14"

(600x600x356) mm. (WхDхH)

(glass door, removable side and back panels)



  • Shipping within 48 h.
  • Return purchased items and get all your money back.
  • Accepting orders 24/7
  • Order overs 999usd this product and earn 100 special loyalty points!
  • Bonus Gift on order overs 999usd

• Rich product size family – five types of height: 6U / 9U / 12U / 15U / 18U;
• Six types of depth:  6" / 14" / 18"  / 21,5" / 24" / 27,5"
• Prefabricated structure in compact flat package;
• Simple upgrade of one section rack into double section rack;
• Leg pieces available;
• Vented back wall;
• Active ventilation option;
• Upper and lower cables glands equipped dust protecting brushes and organizers;
• Superior surface finish;
• Tools & Fittings;
• Competitive price in the bottom price brackets.








5 types of height : 6U/9U/12U/15U/18U;
5 types of height : 150mm./350mm./450mm./
550mm./600mm./700mm.;

From single-sectional
to a double

Some component projects require access to install equipment from all 4 sides while installation, setting up or updating.

Wall mount server cabinet SYSMATRIX WR in types of depth: 350mm, 450mm, 600mm., consist of a supplementary back section which is to be mounted on the wall and serves as the base for the cabinet.

This function is very useful while access is needed for equipment from behind.

There is no need to remove all equipment just add an extra panel while upgrading our project.

On the wall and
floor standing

Now all mount cabinets are equipped
with adjustable legs!

If necessary, wall mount cabinets
could be installed on flat surface.

As an option, SYSMATRIX WR-
series could be equipped
with adjustable legs.

So that a stable positioning of equipment
could be reached.

Easy modernization from a single-sectional to a double-sectional server enclosure can be transformed now.
 
Antirust protection

When a server rack is installed in a technical room, the maintenance is a very important point of the stable work of equipment.

WR-series server rack is equipped with a function protecting against the steam condensation accumulating on the walls.

The construction is provided with back side panel, with a ventilation slot protecting the surface against the condensation.

...compact
packaging,
of course

One more reason you would like to choose SYSMATRIX cabinets in your projects is flat compact packaging!

It is convenient for both: storage and moving.

The construction is supplied unassembled and this allows for 50% and 70% savings of total space!

Three Undisputable Advantages:

1. Savings between 50% and 70% of the rack space during its storage and transportation.

2. Assembled construction allows for delivery and mount the rack at the technical facilities with narrow doorways and/or at the facilities with no cargo elevators.

System integrators and project organizations can only enjoy their work.

Wall mounted server rack 6U 24"x24"  SYSMATRIX WR – convenient for storage and transport.
Easy  assembly and maintained incredible characteristics.

What advantages can you get?  Evaluate multifunctional server rack.
For any project, 6 types of depth are available now: 6" / 14" / 18" / 21,5" /24" / 27,5"

Reliability and solidity of construction reached due to creative solution of the constructor.
Easy modernisation from a single-sectional to a double-sectional server enclosure can be transformed now.
Now, this rack can fit any spot in your home/office. Modern and gorgeous design underscores your creative taste.

And that is not all… Wall mounted server racks WR- series 6U 24"x24"
Assembling construction, designed to accommodate 19 telecommunications, network equipment and automation.
Hi-tech design and high quality of finishing allow placing your equipment in public places and offices.
Huge range of models – over 35 types of sizes are available. Active ventilation can be installed in top and bottom of the rack (optional).

2 in 1 wall mounted and floor standing model (legs optional). Flat and compact packaging saves money on transport and storage.
Wall mounted server rack is not just a metal crate anymore.

The construction is provided with back side panel with a ventilation slot protecting the surface against  condensation.
Wall mounted server racks WR- series are supplied with all necessary tools and fastenings for 19” equipment.
For easy assembling and maintenance all 18" and 24" WR server racks are supplied with side panels.
The construction can easily be transformed from a single to a double section server rack by adding an extra section in the back panel.
It can be done any time without demounting the rack.

2 types of doors:
•Glass in metal frame with perforation
•Solid metal
Framework:
•Prefabricated profile sections
Cable input:
•Top and bottom have dust-tight brush panels with cable managers
Active ventilation:
•Passive – convection heat flow due to perforation front and rear doors
•Active – by setting in the top fan module (all models)
IP protection:
•IP41: glass/perforated door
•IP20: solid metal door
Capacity:
•Static load not exceeding 133 lb.
Material:
•Rolled steel profile
•Frame thickness 2mm; 19” profiles 2mm; other components parts 1.5mm.
Coating:
•Powder paint with degreasing and anticorrosive phosphate
Color:
•Grey: RAL7035
Kit contents:
•Base model includes: set of doors, side panels, 2 pairs (front & rear) 19” profiles, a set of nuts, bolts, washers and screwdriver.

  • Step 1.

    Setting the skeleton.

    Using KIT A, combine bearing profiles 1, top 2 and bottom 3 in one single carcass. Do not tighten the bolts at this step.

  • Step 2.

    Using screws B fasten the roof 2 and the bottom 3 to the bearing profiles 1 in front and behind. You can tighten all elements of the Enclosure now.

  • Step 3.

    Installing the back panel.

    Using the mounting KIT B install the back panel 5 the way most convenient for you.

  • Step 4.

    Installing vertical mounting rails U-mark.

    Using KIT C, install the vertical mounting rails 4 fixing the top and bottom.

  • Step 5.

    Setting the side panels 6 after installing the locks in the handles.

  • Step 6.

    Installing front door.

    Set the door 7 onto the metal pin inserted into the front of the bottom. Pull aside the upper latch and hook the door.

  • *if you want to install the cabinet on the floor,
    on step 1, in the bottom change the screws A
    to the feet 9 and follow the next step.

  • *If you assemble double section cabinet, after step 2,
    set section 8 and follow the next step.

Types of produced sizes
  • Height:6U, 9U, 12U, 15U, 18U;
  • Width:600мм.;
  • Depth:150мм; 350мм; 450мм; 550мм; 600мм; 700мм.
Three types of door
  • glass in a metal frame with perforation;
  • solid metal;
Support framework
  • prefabricated profile sections
Input cable
  • bottom and roof of the enclosure are dust-tight cable entry with cable organizers.
Ventilation
  • passive-convection heat flows due to perforation front doors and enclosure;
  • active-by setting in the roof and/or floor fan element;
Protecting by IP
  • IP41 glass/punching border;
  • P51 solid metal.
Load capability
  • Static load not exceeding 60kg.
Material
  • Rolled steel profile;
  • Carcass thickness: 1,5mm, 19” S-profiles 1,5mm, other component parts 1,2mm.
Coating
  • Powder paint with degreasing and anti-corrosive phosphate.
Color
  • Gray RAL7035.
Kit

Base case system includes: 19” enclosure, a glass door in a metal frame with perforation, a set of side panel, 2 parts of 19” profile, a set of nuts/screws/washers (20un.),screwdriver for assembly.

Marks Descriptions Package (CTNS) G.WT (KGS) Meas (CBM)
WR 6106.**0 19" wall mounted rack 6U 600x150x356 1 9,2 0,03
WR 6306.**0 19" wall mounted rack 6U 600x350x356 1 14,0 0,04
WR 6406.**0 19" wall mounted rack 6U 600x450x356 1 18,0 0,05
WR 6606.**0 19" wall mounted rack 6U 600x600x356 1 21,7 0,07
WR 6109.**0 19" wall mounted rack 9U 600x150x490 1 11,5 0,04
WR 6309.**0 19" wall mounted rack 9U 600x350x490 1 17,0 0,05
WR 6409.**0 19" wall mounted rack 9U 600x450x490 1 21,4 0,06
WR 6609.**0 19" wall mounted rack 9U 600x600x490 1 25,4 0,08
WR 6112.**0 19" wall mounted rack 12U 600x150x623 1 13,0 0,06
WR 6312.**0 19" wall mounted rack 12U 600x350x623 1 20,0 0,07
WR 6412.**0 19" wall mounted rack 12U 600x450x623 1 25,0 0,08
WR 6612.**0 19" wall mounted rack 12U 600x600x623 1 28,9 0,08
WR 6115.**0 19" wall mounted rack 15U 600x150x757 1 16,0 0,07
WR 6315.**0 19" wall mounted rack 15U 600x350x757 1 23,0 0,09
WR 6415.**0 19" wall mounted rack 15U 600x450x757 1 28,5 0,1
WR 6615.**0 19" wall mounted rack 15U 600x600x757 1 35,1 0,1
WR 6118.**0 19" wall mounted rack 18U 600x150x890 1 19,0 0,08
WR 6318.**0 19" wall mounted rack 18U 600x350x890 1 22,5 0,1
WR 6418.**0 19" wall mounted rack 18U 600x450x890 1 34,8 0,12
WR 6618.**0 19" wall mounted rack 18U 600x600x890 1 43,0 0,12

For drawing up of design documentation provide drawings in DWG format.

Description | Diargam | Settings

Nowadays, the modern server equipment is much faster and more powerful than in the past.

As a result, a lot of heat is generated in working space which can affect the performance of whole system, unfortunately, in negative way.

That is why, one of the most important factors impacting the life and reliability of high-priced equipment is the temperature regime in a server rack.

Moreover, most of servers are integrated in public and office environment, were the non-stop cooling fan noise prevents focusing on accomplishing work,

but overheating of the server equipment can cause system crushes and even data loss.

 

All Sysmatrix SR, TR, ER-series server rack cabinets are equipped and pre-installed with Air Control System

– the automatic control of ambient temperature regime and active ventilation in server racks.

The device reads off two temperature gauges, installed in different areas,

and engages 4 fan cooling panel running only when the temperature surpasses the save operating limit. 

The Air Control board is installed into the top of the rack, which save 1U internal space.

            AIR CONTROL SYSTEM :
  • Simple setup, tuning and access
  • Permanent cooling fan noisy elimination.
  •  1U saving on internal space
  • Stable functionality and performance of active equipment
  • Reduced electricity costs
  • Savings on purchasing expensive thermo-control devices
  •  Life extension of  active ventilation components

  • Cut the power cable in half;
  • Strip the blue and brown wires on both male and female ends;
  • Use diagram to plug the Power Supply (male end),
    Cooling panel (female end) and thermosensors to the Air Control System device;
  • Place the Air Control System device into the top panel and plug in;
  • Set the temperature regime.

Parameters

  • power input: 110B/220B;
  • power consumption: <3 Вт;
  • fan and Light output:110B/220B-5;
  • range:19,9-99,9C;
  • two independent channel control,
    two temperature sensors NTC10K.

Settings

The control unit has three types of modes:

  • normal mode;
  • adjustment settings and
  • reset to factory defaults.

While pressing and hold the SET button, it switches to adjustment mode. Hold down the SET button more than 3 seconds, reset to factory default settings. A single press button SET in regulatory regimes or initialization switches to the operating mode. Use the UP- button and DOWN- button to modify the selected parameter.

Code
Function
Content Control
Range
Factory
settings
Note
F1 A channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F2 A channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting range of operation. Use the up and down button peak value. Short press SET to set the default settings
F3 B channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F4 B channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting temperature. Use the up and down having set the temperature value. Short press SET to set the default settings
F5 Temperature correction -10+10 0,0 The calibration function (correction) of reading between the actual temperature and the determined unit
F6 Start-up delay 0-5 2,0 Press and hold the SET button to select the setting delay. Use the up and down to set the desired value. Short press SET to set the default settings.
E1 A channel error A channel self-testing error
E2 B channel error B channel self-testing error
Information
Contact Us

+1 (514) 660-6333