12U 35" Depth Foor Standing Sound Proof Server Cabinet SP 12.900

777.00 USD

Availability: In stock

Quantity of all packages: 1 pcs.

Size of package: 28X34X39 inch.


SP 12.900 

19" Wall Mount Server Rack Cabinet
12U (26"w x35"d x30"h)
(650x900x767mm.) (WxDxH), 

Air Control SYSTEM with sensor, 2 fan, 1 shelf, 1PDU

4 castors, 1 foam cable entry, adjustable U-mark mounting rails.

  • Shipping within 48 h.
  • Return purchased items and get all your money back.
  • Accepting orders 24/7
  • Order overs 999usd this product and earn 100 special loyalty points!
  • Bonus Gift on order overs 999usd

  • - Air Control LCD screen panel with thermo sensor
  • - 2 Build-in Cooling Fans at the top
  • - Up to 36 % noise reduction (Laboratory report attached)
  • - Front and rear Heat Exhaust System
  • - Removable and washable “Dust protector” Filter
  • - Sound proof interior materials and glass / anti-noise protection
  • - 4 heavy duty casters with brakes
  • - Adjustable U-mark 19 in standard rails
  • - 33” - max adjustable distance between U-mounting rails
  • - 2 Latch locks
  • - Mounting Hardware – 20 pcs
  • - Heavy duty doors hinges
  • - Welded and fully-assembled structure, supplied in the wooden crate on pallet.

The Sysracks soundproof server cabinet SP – Series has been designed to reduce (or, completely cut) the working noise from Server A/V and other IT Telecom Equipment as well as prevent the dust and other conducting element from effecting the 19” Standard equipment.
  
By combining ultimate noise reduction with zero overheads and running costs, this model is a popular alternative to a costly dedicated server rooms, by allowing the deployment of servers and network equipment directly in the office/home environment.
 
The SP12.900 model has both Active (cooling fans and Air control system) and Passive (no fans) ventilation capability. Both Active and Passive ventilation relies on the installed IT equipment to draw fresh air in at the side and bottom, and expel it at the Top thought the special ventilation holes.

Heavy Duty and Steel Construction and the spacious internal dimensions (0-33 in between U-rails) provide ample room for almost all types of equipment, allows cable routing throughout the acoustic cabinet, with Dust protective foam cable entry in the bottom of the soundproof enclosure.

 A washable dust-filter, promoting extended equipment life-span and reduced maintenance costs comes in a base model.

Description | Diargam | Settings

Nowadays, the modern server equipment is much faster and more powerful than in the past.

As a result, a lot of heat is generated in working space which can affect the performance of whole system, unfortunately, in negative way.

That is why, one of the most important factors impacting the life and reliability of high-priced equipment is the temperature regime in a server rack.

Moreover, most of servers are integrated in public and office environment, were the non-stop cooling fan noise prevents focusing on accomplishing work,

but overheating of the server equipment can cause system crushes and even data loss.

 

All Sysmatrix SR, TR, ER-series server rack cabinets are equipped and pre-installed with Air Control System

– the automatic control of ambient temperature regime and active ventilation in server racks.

The device reads off two temperature gauges, installed in different areas,

and engages 4 fan cooling panel running only when the temperature surpasses the save operating limit. 

The Air Control board is installed into the top of the rack, which save 1U internal space.

            AIR CONTROL SYSTEM :
  • Simple setup, tuning and access
  • Permanent cooling fan noisy elimination.
  •  1U saving on internal space
  • Stable functionality and performance of active equipment
  • Reduced electricity costs
  • Savings on purchasing expensive thermo-control devices
  •  Life extension of  active ventilation components

  • Cut the power cable in half;
  • Strip the blue and brown wires on both male and female ends;
  • Use diagram to plug the Power Supply (male end),
    Cooling panel (female end) and thermosensors to the Air Control System device;
  • Place the Air Control System device into the top panel and plug in;
  • Set the temperature regime.

Parameters

  • power input: 110B/220B;
  • power consumption: <3 Вт;
  • fan and Light output:110B/220B-5;
  • range:19,9-99,9C;
  • two independent channel control,
    two temperature sensors NTC10K.

Settings

The control unit has three types of modes:

  • normal mode;
  • adjustment settings and
  • reset to factory defaults.

While pressing and hold the SET button, it switches to adjustment mode. Hold down the SET button more than 3 seconds, reset to factory default settings. A single press button SET in regulatory regimes or initialization switches to the operating mode. Use the UP- button and DOWN- button to modify the selected parameter.

Code
Function
Content Control
Range
Factory
settings
Note
F1 A channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F2 A channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting range of operation. Use the up and down button peak value. Short press SET to set the default settings
F3 B channel temperature setting .-19,9C +99,9C 12,0 Press and hold the SET button to select the setting temperature. Use the up and down set temperature value. Short press SET to set the default settings
F4 B channel temperature hytersis 1,0C - 20,0C 2,0 Press and hold the SET button to select the setting temperature. Use the up and down having set the temperature value. Short press SET to set the default settings
F5 Temperature correction -10+10 0,0 The calibration function (correction) of reading between the actual temperature and the determined unit
F6 Start-up delay 0-5 2,0 Press and hold the SET button to select the setting delay. Use the up and down to set the desired value. Short press SET to set the default settings.
E1 A channel error A channel self-testing error
E2 B channel error B channel self-testing error